ONLINE VERSIONProtection from fallingK2 See para 3.2 and Diagram 3.1 for location and dimensions StairEdge of ?oor Edge of ?oorDiagram 3.2 Typical locations for guardingGuarding of areas used for maintenanceFor all buildings3.4 Where people will use the stairs or ladders to access areas for maintenance they should comply with one of the following.a. If access will be required frequently (e.g. a minimum of once per month): follow provisions such as those suggested for dwellings in this Approved Document (see Diagram 3.1).b. If access will be required less frequently than once a month: it may be appropriate to use temporary guarding or warning notices. The Construction (Design and Management) Regulations 2007 and the Work at Height Regulations 2005 give provisions for such measures.3.5 Use signs as specified in the Health and Safety (Safety Signs and Signals) Regulations 1996.Building Regulations 2010 Approved Docu Approved Docu Approved Docu Approved Document K, 2013 edition 25ONLINE VERSIONONLINE VERSIONONLINE VERSION